| Brand Name: | MEASTEK |
| Model Number: | MCTL60A |
| MOQ: | 1 |
| Payment Terms: | T/T,Western Union,MoneyGram |
Mastek MCTL60A High Precision Current Sensor 60A DC-100KHz , 0.1% Accuracy for Power Analysis & Industrial Control
High Accuracy & Wide Bandwidth: 0.1% precision with DC to 100KHz bandwidth, ideal for dynamic current measurement in power systems and industrial drives.
Advanced Core Technology: Utilizes closed-loop fluxgate and multi-point zero-flux technology for stable output and minimal temperature drift.
Robust Safety: 5KV insulation voltage and UL94-V0 certified enclosure, ensuring safe operation in high-voltage environments.
Flexible Installation: Compact design with Φ30mm aperture and multiple mounting holes, suitable for space-constrained applications.
Global Compliance: Meets EN50178 standards, widely used in renewable energy, medical equipment, and smart grid monitoring.
Specifications
| Model | Maximum current | Accuracy | Bandwidth | Current transfer ratio | |
| DC | RMS | ||||
|
MCTL60A |
60A |
60A |
0.1% |
100KHz |
1:1000 |
Electrical properties
| Item | Symbol | Test Conditions | Minimum | Nominal | Maximum | Unit |
| Maximum continuous DC current |
IPN_DC |
- |
60 |
- |
300 |
Adc |
| Corresponding measurement current range (Arms) |
IP |
- |
60 |
- |
300 |
Aac |
| Primary-secondary conversion ratio |
KN |
- |
1:1000 |
- |
1:2000 |
- |
| Rated output current (mArms) |
Isn |
Primary rated current |
60 |
- |
150 |
mA |
| Power supply voltage (±5%) |
Vc |
- |
- |
±15 |
- |
V |
| Power consumption |
Ic |
- |
15mA +Is |
- |
15mA +Is |
MA |
| Load resistance (@Vc=±15V) |
RL |
- |
≤50Ω(@Ip=DC60A) |
- |
≤50Ω(@Ip=DC300A) |
Ω |
| Secondary resistance |
Rs |
- |
≈18 |
- |
≈18 |
Ω |
| Power frequency withstand voltage (50HZ, 1min) |
Vd |
- |
- |
5 |
- |
KV |
| Insulation resistance |
Ri |
- |
- |
>2000MΩ@DC500V |
- |
Ω |
Accuracy Measurement
| Item | Symbol | Test Conditions | Minimum | Nominal | Maximum | Unit |
| Accuracy (@Ta = +25℃) |
XG |
Input DC, full temperature range |
- |
- |
0.1 |
% |
| Linearity error |
EL |
Full range |
- |
- |
0.005 |
% |
|
Offset current (@Ta =+25℃) |
Ioff |
Full temperature range |
- |
- |
≤|±0.004|μA |
μA |
| Response time |
Tr |
di/dt=100A/μs, rise to 90% IPN |
- |
- |
≤1 |
μs |
| Following speed |
di/dt |
- |
>100 |
- |
>100 |
A/μs |
| Frequency range |
f |
- |
0 |
- |
100 |
KHz |
General Features
| Item | Symbol | Test Conditions | Minimum | Nominal | Maximum | Unit |
| Operating temperature range |
Ta |
- |
-40 |
- |
+70 |
℃ |
| Storage temperature range |
Ts |
- |
-45 |
- |
+85 |
℃ |
| Working humidity (no condensation) |
Hw |
- |
20 |
- |
90 |
% |
| Weight |
W |
- |
- |
±203 |
- |
g |
| Execution standard |
St |
EN50178 |
||||
| Casing material |
Encl |
Compliant with UL94-V0 | ||||
Structure Diagram
![]()
| Basic dimensional error |
±0.2mm |
| Primary aperture |
Φ30mm |
| Disc installation |
Bottom:6 x Φ4mm Side:4 x Φ4mm |
| Output terminal |
4-position plug-in terminal |
Packing List
| Name | Quantity |
| Current sensor body | 1 piece |
| Electronic manual | 1 copy |
| Warranty card | 1 piece |